MOX1 MOX-1 AA829-210 Oxygen Gas Sensor for Ventilator Anesthesia Machine and Oxygen Concentration Monitorin

Model Number : MOX1 MOX-1

MOQ : 1

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Delivery Time : 3-5work days

Price : Negotiable

Supply Ability : 5000PCS

Packaging Details : Standard packaging

Place of Origin : USA

Operating Principle : Partial pressure electrochemical

Output : 9 mV to 13 mV in 210 mBar O2

Measurement Range : 0 mBar to 1500 mBar O2

Response Time (T90) : <15 s (air to 100% O2)

Baseline Offset : <200 μV

Linearity : Linear 0% to 100% O2 (See Note1)

Contact Now

MOX1 MOX-1 AA829-210 Oxygen Gas Sensor for Ventilator Anesthesia Machine and Oxygen Concentration Monitorin

Features:

  • Wide measurement range: It can measure oxygen partial pressure from 0 mbar to 1500 mbar, corresponding to an oxygen concentration range of 0% - 100% vol. O2.
  • Fast response: The response time (t90) is less than 15 seconds (from air to 100% O2).
  • Good linearity: It has a linear output from 0% to 100% O2, which meets the requirements of ISO 80601 - 2 - 55.
  • Stable baseline: The baseline offset is less than 200 μV.
  • Temperature compensation: The temperature compensation is less than 2% O2 equivalent in the range of 0 °C to 40 °C.
  • Wide operating temperature range: It can work in the temperature range of -20 °C to +50 °C.
  • Wide operating pressure range: The operating pressure range is 0.5 bar to 2.0 bar.
  • High - humidity resistance: It can operate in an environment with a humidity range of 0% to 99% rh (non - condensing).
  • Low long - term output drift: In 100% O2, the long - term output drift is less than 5% signal loss per year.

Uses:

The MOX1 oxygen sensor is designed to monitor the partial pressure of oxygen in anesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.

Output 9 mv to 13 mv in 210 mbar O2
Measurement Range 0 mbar to 1500 mbar O2
Response Time (t90) < 15 s (air to 100% O2)
Baseline Offset < 200 μV
Temperature Compensation < 2% O2 equivalent (0 °C to 40 °C)
External Load Resistor 10 kΩ minimum
Connector 3 - pin Molex header (Molex 22 - 29 - 2031)
Housing Material White ABS
Weight 39 g (nominal)
Operating Temperature Range - 20 °C to + 50 °C
Operating Pressure Range 0.5 bar to 2.0 bar
Operating Humidity Range 0% to 99% rh (non - condensing)
Long - term Output Drift in 100% O2 < 5% signal loss/year
Recommended Storage Temperature - 10 °C to + 40 °C

MOX1 MOX-1 AA829-210 Oxygen Gas Sensor for Ventilator Anesthesia Machine and Oxygen Concentration Monitorin


Product Tags:

Ventilator Anesthesia Machine Oxygen Gas Sensor

      

MOX1 Oxygen Gas Sensor

      

AA829-210 Oxygen Gas Sensor

      
China MOX1 MOX-1 AA829-210 Oxygen Gas Sensor for Ventilator Anesthesia Machine and Oxygen Concentration Monitorin wholesale

MOX1 MOX-1 AA829-210 Oxygen Gas Sensor for Ventilator Anesthesia Machine and Oxygen Concentration Monitorin Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ShenzhenYijiajie Electronic Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0